| After-sales Service: | All Series |
|---|---|
| Warranty: | All Series |
| Max Diameter of Workpiece: | <500mm |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency



Ratio testing range | 1~10000 | High output | Precision:2%, Max Current:2000mA, Capacity:2000VA, 0.5KV~10KV (0.1KV step) | Input voltage | AC 220V |
Group Testing range | 1~12 | Self-excited power | AC 0~50V/15A, Multi-frequencies (45-65Hz), Auto dual frequency | Output voltage | AC 0~80KV/100KV |
Accuracy | 1~1000,0.2 | Resolving power | tan delta:0.001% Capacitance:0.001pF | Voltage boosting speed | 2KV/S10% |
1000~10000,0.5 | CVT range | 10-1000 | Accuracy degree | 3 | |
Power | AC23010%,50HZ | Accuracy | 0.1% | Number of times of continuous test | 1~9 |
Temperature | -20°C~40°C | Measuring range | Capacitance (Cx): 1.5pF < Cx < 300nF | Stirring time | 0~99 seconds |
Relative humidity | <85% | Standing time | 0-9 minutes 59 seconds |



Output Voltage | 0~100KV | Charging Voltage | 0–400 V | Linear Scan Distribution | (1kHZ)- (2kHZ),2000 scan frequency point, resolution:1kHZ |
Voltage Distortion Rate | <3% | Pulse Waveform | Wavefront 0.5 μs, Wave tail 6500 μs | Sectional scan measurement distribution | (0.5kHz)~(1MHz),2000 scan frequency |
Voltage Raising Speed | 0.5~5KV/S | Pulse Frequency | 25 Hz (3 Hz with external Cs) | (0.5kHz)~(10kHz) | |
Stand Time | 15min(adjustable) | Cutoff Time | 0.μs~16μs | (10kHz)~(100kHz) | |
Boosting Interval | 5min(adjustable) | Charging Capacitor Cs | Range: 4.7 nF – 1000 nF (External supported, Max 10 μF) | (100kHz)~(50kHz) | |
Boosting Frequency | 1~6time(s) | Wave tail resistance Rs | Range: 3.3 Ω – 4.7 kΩ (External supported) | (500kHz)~(1000kHz) | |
Booster Capacity | 1.5KVA | Wave tail resistance Rp | Range: 10 Ω – 15 kΩ (External supported) | ||
System Inductance L | 0–100 μH | ||||
Load Capacitance | 0.47 nF – 168 nF (External supported) |


Capacitance range | 6pF-250μF | Working power supply | Built 12.6V/4.8AH Lithium battery |
Sensitivity | 0.1pc | Output current | 5mA,100mA,300mA,1A,10A |
Measurement channel | 2pcs independent channels | Measuring range | 0~20kΩ |
Sampling Accuracy | 12Bit | Accuracy | (0.2%RD0.05%FS) |
Sampling rate | Max. 100MHz per channel | Minimum resolution | 1μΩ |
Measurement range | 0.1pc~100000pc | Display | Positive display LCD screen |
Dynamic range | >80db | Power supply | AC220V22V,50Hz2Hz |
Measurement frequency band | 10KHz~1MHz at 3db | ||
Frequency range of test power | 50-400Hz | ||
Programmable filter | Low frequency 10K, 20K, 40K, 80K; High frequency 100K, 200K, 300K, 1000K | ||
Environmental temperature | -15℃~50℃ |